STREAM version $Revision: 5.8 $
-------------------------------------------------------------
This system uses 8 bytes per DOUBLE PRECISION word.
-------------------------------------------------------------
Array size = 32000000, Offset = 0
Total memory required = 732.4 MB.
Each test is run 10 times, but only
the *best* time for each is used.
-------------------------------------------------------------
Printing one line per active thread....
-------------------------------------------------------------
Your clock granularity/precision appears to be 1 microseconds.
Each test below will take on the order of 115601 microseconds.
   (= 115601 clock ticks)
Increase the size of the arrays if this shows that
you are not getting at least 20 clock ticks per test.
-------------------------------------------------------------
WARNING -- The above is only a rough guideline.
For best results, please be sure you know the
precision of your system timer.
-------------------------------------------------------------
Function      Rate (MB/s)   Avg time     Min time     Max time
Copy:        3690.1134       0.1397       0.1387       0.1447
Scale:       3737.1394       0.1384       0.1370       0.1457
Add:         4588.8560       0.1677       0.1674       0.1685
Triad:       4587.3791       0.1678       0.1674       0.1680
-------------------------------------------------------------
Solution Validates
-------------------------------------------------------------